Model: G01-CO2-N Series Key words:
CO2/Temperature/Humidity detection RS485 with BACnet MS/TP Analog linear output Wall mounting BACnet CO2 transmitter with temperatue and relative humidity detection, white backlit LCD displays clear readings. It can provide one, two or three 0-10V / 4-20mA linear outputs to control a ventilation system, BACnet MS/TP connection was integrated to BAS system. The measuring range can be up to 0-50,000ppm.
Model: TGP Series Key words: CO2/Temperature/Humidity detection External sensor probe Analog linear outputs
It is mainly used in the application of BAS in industrial buildings to real time monitoring carbon dioxide level, temperature and relative humidity. Also suitable for applications in plant areas such as mushroom houses. The lower right hole of the shell can provide expandable use. The external sensor probe to avoid internal heating of the transmitter from affecting measurements. White backlight LCD can display CO2, Temp and RH if required. It can provide one, two or three 0-10V / 4-20mA linear outputs and a Modbus RS485 interface.
Model: G01-CO2-B5 Series Key words:
CO2/TVOC/Temperature/Humidity detection Wall mounting/ Desktop On/off output optional Indoor air quality monitor of CO2 plus TVOC(mix gases) and temperature, humidity monitoring. It has tri-color traffic display for three CO2 ranges. The buzzle alarm is available which can be turned off once the buzzer rings. It has the optional on/off output to control a ventilator according to CO2 or TVOC measurement. It supports power supply: 24VAC/VDC or 100~240VAC, and can be easily mounted on the wall or placed on a desktop. All parameters can be preset or adjusted if required.
Model: G01-IAQ Series Key words: CO2/TVOC/Temperature/Humidity detection Wall mounting Analog linear outputs CO2 plus TVOC transmitter, with temperature & relative humidity, also combined both humidity and temperature sensors seamlessly with the digital auto compensation. White backlit LCD display is option. It can provide two or three 0-10V / 4-20mA linear outputs and a Modbus RS485 interface for different applications, which was easily integrated into building ventilation and commercial HVAC system.
Model: TG9-CO2+VOC Key words: CO2/TVOC/Temperature/Humidity detection Duct installation Analog linear outputs Real time detect carbon dioxide plus tvoc (mix gases) of the air duct, also optional temperature and relative humidity. A smart sensor probe with the water-proof and porous film can be easily installed into any air duct. LCD display is available if required. It provides one, two or three 0-10V / 4-20mA linear outputs. The end user can adjust CO2 range which correspond with the analog outputs via Modbus RS485, also can preset the inverse proportion liner outputs for some different applications.