Model: F2000TSM-CO-C101 Key words: Carbon dioxide sensor Analog linear outputs RS485 interface Low-cost carbon monoxide transmitter for ventilation systems. Within a high quality Japanese sensor and its long lifetime support, the linear output of 0~10VDC/4~20mA is stable and reliable. Modbus RS485 communication interface has 15KV anti-static protection which can connect to a PLC to control ventilation system.
Model: TSP-CO Series
Key words: CO/Temperature/Humidity monitor Analog linear outputs On/off relay outputs Buzzer alarm RS485 with BACnet MS/TP Real-time monitoring carbon monoxide concentration and temperature. OLED screen displays CO and Temperature in real time. Buzzer alarm is available. It has a stable and reliable 0-10V / 4-20mA linear output, and two relay outputs, RS485 in Modbus RTU or BACnet MS/TP. It usually be used in parking, BMS systems and other public places.
Model: TKG-CO Series
Key words: CO/Temperature/Humidity detection Analog linear output and optional PID output On/off relay outputs Buzzer alarm Underground parking lots RS485 with Modbus or BACnet
Design for control carbon monoxide concentration in undergroung parking lots or semi underground tunnels. With a high quality Japanese sensor it provides one 0-10V / 4-20mA signal output to integrate into PLC controller, and two relay outputs to control ventilators for CO and Temperature. RS485 in Modbus RTU or BACnet MS/TP communication is optional. It displays carbon monoxide in real time on the LCD screen, also optional temperature and relative humidity. The design of external sensor probe can avoid internal heating of the controller from affecting measurements.
Model: GX-CO Series
Key words: CO/Temperature/Humidity monitor Avaliable Zero calibration Replaceable CO sensor Strong control setting and outpus Real-time monitoring air carbon monoxide concentration, displaying CO measurements and 1-hour average. Temperature and relative humidity is optional. High quality Japanese sensor has five years liftime and is replaceable conveniently. Zero calibration and CO sensor replacement can be handled by end users. It provides one 0-10V / 4-20mA linear output, and two relay outputs, and optional RS485 with Modbus RTU. Buzzer alarm is available or disable, it’s widely used in BMS systems and ventilation control systems.
Model: G09-O3 Key words: Analog outputs Relay dry contact outputs RS485 3-color backlight display Buzzle alarm
Real-time monitoring air ozone and optional temperature and humidity. Ozone measurements have temperature and humidity compensation algorithms. It provides one relay output to control a ventilator or ozone generator. One 0-10V/4-20mA linear output and a RS485 to connect a PLC or other control system. Tri-color traffic LCD display for three ozone ranges. The buzzle alarm is available.
Model: TSP-O3 Series Key words: OLED display optional Analog outputs Relay dry contact outputs RS485 with BACnet MS/TP Buzzle alarm Real-time monitoring air ozone concentration . Alarm buzzle is available with setpoint preset. Optional OLED display with operation buttons. It provides one relay output to control an ozone generator or ventilator with two control way and setpoints selection, one analog 0-10V/4-20mA output for ozone measurement.