CO Sensor and Controller
-
Carbon Monoxide Monitor
Model: TSP-CO Series
Carbon monoxide monitor and controller with T & RH
Sturdy shell and cost-effective
1xanalog linear output and 2xrelay outputs
Optional RS485 interface and availalbel buzzer alarm
Zero point calibration and replaceable CO sensor design
Real-time monitoring carbon monoxide concentration and temperature. OLED screen displays CO and Temperature in real time. Buzzer alarm is available. It has a stable and reliable 0-10V / 4-20mA linear output, and two relay outputs, RS485 in Modbus RTU or BACnet MS/TP. It usually be used in parking, BMS systems and other public places. -
Carbon Monoxide Monitor and Controller
Model: GX-CO Series
Carbon monoxide with temperature and humidity
1×0-10V / 4-20mA linear output, 2xrelay outputs
Optional RS485 interface
Zero point calibration and replaceable CO sensor design
Powerful on-site setting function to meet more applications
Real-time monitoring air carbon monoxide concentration, displaying CO measurements and 1-hour average. Temperature and relative humidity is optional. High quality Japanese sensor has five years liftime and is replaceable conveniently. Zero calibration and CO sensor replacement can be handled by end users. It provides one 0-10V / 4-20mA linear output, and two relay outputs, and optional RS485 with Modbus RTU. Buzzer alarm is available or disable, it’s widely used in BMS systems and ventilation control systems. -
Basic Carbon Monoxide Sensor
Model: F2000TSM-CO-C101
Key words:
Carbon dioxide sensor
Analog linear outputs
RS485 interface
Low-cost carbon monoxide transmitter for ventilation systems. Within a high quality Japanese sensor and its long lifetime support, the linear output of 0~10VDC/4~20mA is stable and reliable. Modbus RS485 communication interface has 15KV anti-static protection which can connect to a PLC to control ventilation system. -
CO controller with BACnet RS485
Model: TKG-CO Series
Key words:
CO/Temperature/Humidity detection
Analog linear output and optional PID output
On/off relay outputs
Buzzer alarm
Underground parking lots
RS485 with Modbus or BACnetDesign for control carbon monoxide concentration in undergroung parking lots or semi underground tunnels. With a high quality Japanese sensor it provides one 0-10V / 4-20mA signal output to integrate into PLC controller, and two relay outputs to control ventilators for CO and Temperature. RS485 in Modbus RTU or BACnet MS/TP communication is optional. It displays carbon monoxide in real time on the LCD screen, also optional temperature and relative humidity. The design of external sensor probe can avoid internal heating of the controller from affecting measurements.